Additional Features & Benefits |
|
| |
Tamper proof
The hour meter is stored in EEPROM
and remains regardless of connection to the power
supply.
Low voltage cut-out
An internal relay
provides a cut-out at 80% discharge. This can operate
warning alarms or disable functions such as lift pump
motors.
Compatible with all battery
technologies
The discharge curve selector
allows optimization of the PowerGauge™
for all applications.
Opportunity partial recharge
recognition
The superior monitoring algorithms
are able to track battery state of charge following
opportunity partial recharges irrespective of if the
PowerGauge™ remains
connected during the charging process.
|
|
| |
Dimensions
 |
|
|
General Specifications*
|
Part number |
900/30001 |
900/30002 |
900/30003 |
|
Operating voltage |
24 VDC |
36 VDC |
48 VDC |
|
Max. current consumption: |
35 mA |
35 mA |
25mA |
|
LCD display |
6 digits, numeral size 4.5 mm |
|
LED bar graph displays |
10 (5 green, 3 yellow, 2 red) |
|
VCounting range |
0-99999.9 h |
|
Partial recharges |
are displayed |
|
Data storage |
EEPROM |
|
Relay contact |
Voltage free (opens when reaching
discharge voltage) |
|
Swiching capacity |
5 A |
3 A |
2 A |
|
Relay restart |
After relay cutoff one sigle
restart for 30 s possible |
|
Signal input |
min. pulse time 0.5 s |
|
Housing |
plastic (black) |
|
Weight (approx.) |
100 g |
|
Connector |
8-pole Molex Mini-fit Jumior |
|
Ambient temperature: |
-30ºC to +70ºC |
|
Storage temperature: |
-40ºC to +80ºC |
|
Vibration / shock: |
EN60068-2-34 (1G, 10-500 Hz)
SAEJ1378 (20 G, 10-80 Hz) |
|
Shock |
EN60068-2-27 (30 G, 18 ms) /
EN60068-2-29 (25 G, 6 ms) /
SAE J1378 (55 G, 10 ms) |
|
EMC |
EN55011, EN61000-6-2 |
|
Ingress of dust and water: |
IP65 |
|